Sign in →

Catalog ID XMatch Crossmatch

CPOE Test Name

Order a Type and Cross. Reflex crossmatch order by Blood Bank when a RBC order is received

Synonyms

Type and Cross, Crossmatch, Compatibility Testing, Type & Screen with Crossmatch

Specimen Requirements

Fenwal Label. Requires Full Name, Medical Record Number, date and phlebotomist initials/Cerner ID. Pink top (EDTA) tube. A current type and screen must be performed before performing a crossmatch

Storage and Transport

Send to Blood Bank

Causes for Rejection

Improper labeling; wrong tube; gross hemolysis; insufficient volume

Interpretation

A compatible crossmatch and negative antibody screen result indicates that testing did not identify any antibody or incompatibility.

Test Consists

ABO, Rh(D) type, and antibody screen test on each specimen submitted per 72 hours. A crossmatch is completed per Red Blood Cell unit requested.

Turn Around Time

Crossmatch (Red Blood Cells)
Routine: 2 – 4 hours Urgent: 1 – 2 hours
Emergent: 30 minutes
Emergency, uncrossmatched: 15 minutes

Methodology

Immediate spin, 37 deg C LISS phase, AHG phase.

CPT / HCPCS Code

86922, 86920

Reference Ranges

Incompatible crossmatch requires specialized testing and time to identify the cause. A Transfusion Risk form is indicated in an emergency situation to release incompatible blood. It must be signed by the recipient’s physician or designee who is responsible for M.D. notification.

Performing Lab

Blood Bank BI-1230 721-2731