Sign in →

Catalog ID XMatch Crossmatch

CPOE Test Name

Order a Type and Cross. Reflex crossmatch order by Blood Bank when a RBC order is received

Synonyms

Type and Cross, Crossmatch, Compatibility Testing, Type & Screen with Crossmatch

Specimen Requirements

Fenwal Label. Requires Full Name, Medical Record Number, date and phlebotomist initials/Cerner ID. Pink top (EDTA) tube. A current type and screen must be performed before performing a crossmatch

Causes for Rejection

Improper labeling; wrong tube; gross hemolysis; insufficient volume

Turn Around Time

Crossmatch (Red Blood Cells)
Routine: 2 – 4 hours Urgent: 1 – 2 hours
Emergent: 30 minutes
Emergency, uncrossmatched: 15 minutes

CPT / HCPCS Code

86922, 86920

Storage and Transport

Send to Blood Bank

Reference Ranges

Incompatible crossmatch requires specialized testing and time to identify the cause. A Transfusion Risk form is indicated in an emergency situation to release incompatible blood. It must be signed by the recipient’s physician or designee who is responsible for M.D. notification.

Interpretation

A compatible crossmatch and negative antibody screen result indicates that testing did not identify any antibody or incompatibility.

Methodology

Immediate spin, 37 deg C LISS phase, AHG phase.

Test Consists

ABO, Rh(D) type, and antibody screen test on each specimen submitted per 72 hours. A crossmatch is completed per Red Blood Cell unit requested.

Performing Lab

Blood Bank BI-1230 721-2731