Sign in →

Catalog ID TMP Trimethoprim, Serum

Important Note

Order: Ref Misc Referral Lab Test

Comment: Trimethoprim

Reporting Name

Trimethoprim, S

Useful For

Monitoring trimethoprim therapy to ensure drug absorption, clearance, or compliance


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (gel tubes/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. Serum for a peak level should be collected at least 60 minutes after a dose.

2. Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.


AUMC Laboratory Catalog Note:

Collect 2.0 mL blood in Red top tube.

Reference Values

>2.0 mcg/mL (Peak)

Day(s) Performed

Monday, Thursday

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum Red

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

80299

LOINC Code Information

Test ID Test Order Name Order LOINC Value
TMP Trimethoprim, S 11005-6

 

Result ID Test Result Name Result LOINC Value
80146 Trimethoprim, S 11005-6

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Forms

If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.

Report Available

2 to 5 days

Secondary ID

80146