Sign in →

Catalog ID SLA IgG Soluble Liver Antigen Antibody, IgG

Additional Codes

CPOE: Ref Soluble Liver Antigen Antibody, IgG

DOE: Ref SLA IgG

Specimen

Gold SST tube, collect 2.0 mL blood

Serum, 1.0 mL (0.3 mL minimum), refrigerated

Rejection Criteria

Plasma, other body fluids, contaminated specimen, heat-inactivated specimen, hemolyzed specimen, lipemic specimen, insufficient quantity, specimen at room temperature >48 hours

Interpretative Information

The presence of SLA antibodies has almost 100% specificity for autoimmune hepatitis, although only 12-30% have these antibodies.  Thus, a negative SLA IgG test does not rule out autoimmune hepatitis.

Performing Lab

ARUP Laboratories

Turn-Around-Time

1 - 4 days (performed on Sundays, Tuesdays, and Thursdays)

Reference Values

0.0-20.0 U Negative
20.1-24.9 U Equivocal
Greater than or equal to 25.0 U Positive