Catalog ID ROM+ Rupture of Membranes (ROM+)
Additional Codes
CPOE: Rupture of Membranes Test
Specimen
ROM+ collection kit stored in OBED. Transport to Core lab following collection ASAP.
Rejection Criteria
Grossly bloody specimens, unlabeled specimens, specimens older than 6 hours
Interpretative Information
The Rupture of [fetal] Membranes Test (ROM+) qualitatively detects the presence of IGFBP-1 and AFP protein markers of amniotic fluid in vaginal secretions. Since elevated AFP levels can be associated with various fetal developmental disorders such as neural-tube defects, hypothyroidism, autoimmune state, congenital heart defects, and cystic fibrosis, positive results should be clinically correlated with signs, symptoms or complaints suggestive of rupture of membranes.
CPT Code
84112
Performing Lab
AUMC Core Lab - Chemistry, AD3301, 706-721-2120