Catalog ID Eos Ct Eosinophil Count

CPOE Test Name

Eosinophil Count Automated

Synonyms

EOS count, Absolute eosinophil count

Specimen Type

Blood

Specimen Requirements

Lavendar Top (EDTA) tube; 2.0 mL blood for venipuncture, 500µL for capillary EDTA microtainer collection

Storage and Transport

Room temperature

Special Instructions

Always allow blue top/citrate tubes to fill completely.

Causes for Rejection

Insufficent quantity; wrong tube; improper labeling; clotted

Reference Range

0 – 0.5 thousand/mm3

Turn Around Time

4 hours

Performing Lab

Core Laboratory BI 2023 721-2120

Methodology

VCS Methodology

CPT/HCPCS Code

85048

CPT / HCPCS Code