Catalog ID CBCD Complete Blood Count with Differential
CPOE Test Name
CBC with Diff
Epic EAP Test Code
LAB293
Synonyms
Differential, Diff slide, WBC differential, CBCD
Specimen Type
Blood
Specimen Requirements
Lavendar Top (EDTA) tube; 2.0 mL blood for venipuncture, 500µL for capillary EDTA microtainer collection
Causes for Rejection
Wrong container; improper labeling; insufficient quantity; no concurrent white blood cell count
Turn Around Time
2 hours
Performing Lab
Core Laboratory BI-2023 721-2120 ; Cancer Center Lab AM-2610 721-1739; Family Medicine Laboratory BP-1148 721-4596; Pediatric Teaching Laboratory BP-3230 721-9729
Critical Values
Blasts on patients with no history of leukemia. Platelet count of 50,000 with no history.
Storage and Transport
Room temperature
Reference Range
https://www.medialabinc.net/dv/dl.aspx?d=68104&dh=5c6f0&u=64389&uh=bbf51
Test Consists
Percentage of white blood cells, RBC morphology, Platelet evaluation. A slide review is automatically done if a laboratory defined abnormality is found during analysis of the electronic differential done as part of a CBC with differential.
Methodology
Microscopic analysis of Wright-stained peripheral.
CPT/HCPCS Code
85007