Sign in →

Catalog ID ATIII Antithrombin

CPOE Test Name

ATIII

Synonyms

AT-III

Specimen Type

Plasma

Specimen Requirements

Light Blue Top (Sodium Citrate) tube; 2.7 mL blood

Storage and Transport

Room temperature. Transport to the lab immediately.

Causes for Rejection

Wrong container; insufficient quantity; improper labeling;clotted; hemolyzed

Reference Range

84 – 123.0%

Turn Around Time

1 Hour

Performing Lab

Core Laboratory BI 2023 721-2120

Interpretation

Low values may predispose patient to thrombosis.

CPT/HCPCS Code

85300

CPT / HCPCS Code

85300